GWF-IC
Structure of Blocks
FOR EACH SIMULATION
BEGIN OPTIONS
[EXPORT_ARRAY_ASCII]
[EXPORT_ARRAY_NETCDF]
END OPTIONS
BEGIN GRIDDATA
STRT [LAYERED] [NETCDF]
<strt(nodes)> -- READARRAY
END GRIDDATA
Explanation of Variables
Block: OPTIONS
EXPORT_ARRAY_ASCIIkeyword that specifies input griddata arrays should be written to layered ascii output files.EXPORT_ARRAY_NETCDFkeyword that specifies input gridded arrays should be written to the model output NetCDF file with attributes that support using the generated file as a MODFLOW 6 simulation input. This option only has an effect when an output model NetCDF file is configured and the simulation is run in VALIDATE mode, otherwise it is ignored.
Block: GRIDDATA
strtis the initial (starting) head—that is, head at the beginning of the GWF Model simulation. STRT must be specified for all simulations, including steady-state simulations. One value is read for every model cell. For simulations in which the first stress period is steady state, the values used for STRT generally do not affect the simulation (exceptions may occur if cells go dry and (or) rewet). The execution time, however, will be less if STRT includes hydraulic heads that are close to the steady-state solution. A head value lower than the cell bottom can be provided if a cell should start as dry.
Example Input File
#The OPTIONS block is optional
BEGIN OPTIONS
END OPTIONS
#The GRIDDATA block is required
BEGIN GRIDDATA
STRT LAYERED
CONSTANT 0.0 Initial Head layer 1
CONSTANT 0.0 Initial Head layer 2
END GRIDDATA